NEMA Enclosure Types

2023-07-26 14:14:44 Young 80

NEMA MOTOR


Non-Hazardous Locations

Type 1 : General Purpose - Indoor

  • Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dirt.

Type 2 : Drip-Proof - Indoor

  • Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment, to provide a degree of protection against falling dirt, and to provide a degree of protection against dripping and light splashing of liquids.

Type 3 : Dusttight, Raintight, Sleettight - Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, and windblown dust; and that will be undamaged by the external formation of ice on the enclosure.

Type 3R : Raintight, Sleet Resistant - Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, and snow; and that will be undamaged by the external formation of ice on the enclosure.

Type 3S : Dusttight, Raintight, Sleettight - Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, and windblown dust; and in which the external mechanism(s) remain operable when ice laden.

Type 4 : Watertight, Dusttight, Sleet Resistant - Indoor & Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose-directed water; and that will be undamaged by the external formation of ice on the enclosure.

Type 4X : Watertight, Dusttight, Corrosion-Resistant - Indoor & Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed water, and corrosion; and that will be undamaged by the external formation of ice on the enclosure.

Type 5 : Dusttight, Drip-Proof - Indoor

  • Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against settling airborne dust, lint, fibers, and flyings; and to provide a degree of protection against dripping and light splashing of liquids.

Type 6 : Occasionally Submersible, Watertight, Sleet Resistant - Indoor & Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against hose-directed water and the entry of water during occasional temporary submersion at a limited depth; and that will be undamaged by the external formation of ice on the enclosure.

Type 6P : Watertight, Sleet Resistant Prolonged Submersion - Indoor & Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against hose-directed water and the entry of water during prolonged submersion at a limited depth; and that will be undamaged by the external formation of ice on the enclosure.

Type 12 : Dusttight and Driptight - Indoor

  • Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; and against dripping and light splashing of liquids.

Type 12K : Dusttight and Driptight, with Knockouts - Indoor

  • Enclosures constructed (with knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; and against dripping and light splashing of liquids.

Type 13 : Oiltight and Dusttight - Indoor

  • Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; and against the spraying, splashing, and seepage of water, oil, and noncorrosive coolants.

For enclosures used in

Hazardous Locations

Type 7 : Class I, Group A, B, C or D Hazardous Locations - Indoor

  • Enclosures constructed for indoor use in hazardous locations classified as Class I, Division 1, Groups A, B, C, or D as defined in NFPA 70.

Type 8 : Class I, Group A, B, C or D Hazardous Location - Indoor & Outdoor

  • Enclosures constructed for either indoor or outdoor use in hazardous locations classified as Class I, Division 1, Groups A, B, C, and D as defined in NFPA 70.

Type 9 : Class II, Group E, F or G Hazardous Locations - Indoor

  • Enclosures constructed for indoor use in hazardous locations classified as Class II, Division 1, Groups E, F, or G as defined in NFPA70.

Type 10 : Requirements of Mine Safety and Health Administration

  • Enclosures constructed to meet the requirements of the Mine Safety and Health Administration, 30 CFR, Part 18.

For more detailed and complete information, NEMA Standards Publication 250-2003, Enclosures for Electrical Equipment (1000 Volts Maximum) should be consulted.


Phone Number
Inquiry Form
E-Mail
主站蜘蛛池模板: 四虎影视8848a四虎在线播放 | 黄页网址免费观看 | 亚洲第一免费网站 | 亚洲狠狠婷婷综合久久久久网站 | 99视频在线国产 | 欧美在线一区二区三区 | 中文字幕在线不卡精品视频99 | 精品福利视频网站 | 久久久国产精品网站 | 国产在线观看一区二区三区 | 香蕉网站狼人久久五月亭亭 | 69国产成人综合久久精品91 | 黄色一级免费大片 | 中文字幕综合久久久久 | 欧美精品黄页在线观看视频 | 中文字幕综合网 | 欧美在线一区二区三区精品 | 超级碰碰青草免费视频92 | 一本久道久久综合中文字幕 | 久久www免费人成_看 | 亚洲色大成网站www久久九九 | 美国俄罗斯毛片一区二区 | 欧美视频网页 | 欧美精品国产综合久久 | 国产精品免费_区二区三区观看 | 制服丝袜在线视频香蕉 | 精品国产一区二区三区不卡 | 色聚网久久综合 | 国产一区免费观看 | 在线亚洲欧洲国产综合444 | 69av美女 | 日韩视频不卡 | 国产一级毛片大陆 | 精品69久久久久久99 | 69国产成人精品午夜福中文 | 激情四播| 日本一区二区三区不卡在线看 | 亚洲成人在线免费观看 | 天天爽天天色 | 黄页网站免费男人观看 | 色欧美色 |